| Rated Capacity LBS/HR @ 60 degrees F. 100 psig GAL/HR | Rated Capacity LBS/HR @ 60 degrees F. 100 psig CF/HR | KW | Amps/Line 480V-3 ph 50/60 Hz | Conduit size Heater Circuit IN. | Number of Lines | Shell O.D. IN. | LPG Inlet | LPG Outlet | Approx. Overall Length IN. | Approx. Overall Height IN. | Ransome Model |
| 25 | 911 | 8 | 10A | .75 | 3 | 4.5 | 2" NPT | 2" NPT | 56 | 24 | RETH25 |
| 50 | 1,822 | 16 | 19A | .75 | 3 | 8.625 | 2" NPT | 2" NPT | 36 | 30 | RETH50 |
| 80 | 2,916 | 25 | 31A | .75 | 3 | 8.625 | 2" NPT | 2" NPT | 45 | 30 | RETH80 |
| 160 | 5,832 | 50 | 30A | 1 | 6 | 10.75 | 2" NPT | 3" 300 CL | 64 | 32 | RETH160 |
| 240 | 8,748 | 75 | 45A | 1 | 6 | 10.75 | 2" NPT | 3" 300 CL | 82 | 32 | RETH240 |
| 320 | 11,664 | 100 | 40A | 1.25 | 9 | 12.75 | 3" 300 CL | 3" 300 CL | 74 | 36 | RETH320 |
| 400 | 14,580 | 125 | 50A | 1.25 | 9 | 12.75 | 3" 300 CL | 3" 300 CL | 92 | 36 | RETH400 |